(a)Equivalent rotor current per phase(in A)=   
 
    52.083013 - 16.233666i  
 
 (b)Stator current per phase(in A)=   
 
    55.016346 - 40.678111i  
 
 (c)Power factor=   
 
    0.8040793  
 
 (d)Rotor input(in watt)=   
 
    22321.291  
 
 (e)Rotor copper losses(in watts)=   
 
    892.85165  
 
 (f)Torque(in N-m)=   
 
    284.20351  
 
 (g)Mechanical power output from rotor(in watts per phase)=   
 
    21178.44  
 
 (h)Stator input(in watts per phase)=   
 
    24207.192  
 
 (i)Efficiency (in %)=   
 
    87.488211  
 